A heater that leaks in the field costs more than the heater itself - drained tanks, lost production, service call. We test every unit before it leaves the shop.
Test 1: Underwater air pressure
Seal the open end of the tube. Blow 0.5 MPa air into the tube. Submerge in a water tank. Watch for 60 seconds. No bubbles = the welds are hermetic. Any bubble = grind and reweld.
Test 2: Insulation resistance (megger)
500V DC between the terminal and the metal sheath. Should read above 100 M ohm. Below 50 M ohm means the MgO is damp. We bake the heater at 200 C for 4 hours and retest.
Test 3: Ground continuity
Measure resistance between the flange and any bare metal part. Should read under 0.1 ohm. If the ground wire is not bonded to the flange, the customer gets a shock hazard.
Test 4: Dielectric withstand
For immersion heaters, apply 1500V AC between terminal and sheath for 1 second. No breakdown. This catches tiny pinholes that the megger misses.
Every heater we ships has a test tag with the megger reading and pressure test result. Customers in Europe and North America require this for CE and UL. We do it for everyone.
Need tested, documented heaters?
Every unit comes with a test tag. We can provide full test reports on request.
Send Your Specs