Steam turbines in power plants have casing bolts up to 100 mm diameter. You cannot torque them cold - the gasket leaks. You heat them in place, stretch them, then torque.
The process
- Insert a bolt heater rod into the hollow bolt
- Heat to 300 to 400 C for 15 to 30 minutes
- Bolt stretches 0.1 to 0.2 mm per 100 mm length
- Torque the nut while hot
- Pull the rod out, let the bolt cool and clamp the flange
Rod specs
Bolt heater rods are single-ended cartridge heaters, 10 to 20 mm diameter, 500 to 2000 mm long. Sheath is Incoloy 800 because they run at 400 C in still air. Watt density is low - 2 to 3 W/cm2 - because there is no liquid to cool them.
AC vs DC
Large rods run on 220V or 380V. We build both. DC is used on-site where power plants have DC backup, but most service trucks use 220V.
A power plant in Shanxi used our 16 mm x 1500 mm bolt rods on a 300 MW turbine. They heat 80 bolts per overhaul. The rods last 200+ cycles. We replaced cheaper ones that failed after 30 cycles.
Need turbine bolt heaters?
Tell us bolt diameter, hole depth and voltage. We build to your drawing.
Send Your Specs