Welding Titanium Heaters: The 400 C Rule and Argon Purge

Titanium sheath heaters go into seawater, chloride and acid tanks. Titanium resists corrosion that eats through stainless in weeks. But welding titanium is unforgiving.

The 400 C rule

Above 400 C, titanium reacts with oxygen, nitrogen and hydrogen in the air. The weld zone becomes brittle - like glass. It cracks on cooling. This is not just the weld pool - the heat affected zone (HAZ) on both sides also must be shielded.

How we weld it

Filler

ERTi-2 matching grade. No copper brushes, no steel tools - titanium must be welded with dedicated tools. Iron contamination on titanium causes rust spots in service.

A seawater filter press in Qingdao had titanium heaters failing in 4 months. We cut one open - the weld was blue and brittle. We welded new ones with full purge and trailing shield. They have run 4 years.

Need titanium heaters for chloride service?

We purge both sides and use dedicated Ti tools. Every weld is silver.

Send Your Specs