Almost every heater we ship has a thermocouple for closed-loop control. The two most common types are K-type (chromel-alumel) and J-type (iron-constantan). Picking the wrong one gives you a wrong reading.
K-type
- Range: -200 to 1200 C
- Most common, cheapest and most available
- Good for furnaces, ovens, hot runners
- Accuracy: +/-1.5 C
J-type
- Range: -40 to 750 C
- More stable below 400 C than K-type
- Iron leg oxidizes fast in high-temp air
- Common in plastics and packaging machinery
PT100 RTD
Below 600 C where you need tight accuracy (+/-0.15 C), use a PT100. It is more expensive but is the reference standard. We use PT100 in precision ovens.
Rule of thumb: above 600 C use K-type. Below 400 C where stability matters use J-type. Where precision matters use PT100. If unsure, K-type works for 90 percent of jobs.
Need thermocouples matched to your heaters?
Tell us the temperature range and how the probe mounts. We will build it to spec.
Get Thermocouples