The temperature sensor on your oven or heater decides how accurate your reading is. Two choices: RTD (PT100) or thermocouple.
RTD (PT100)
A platinum resistor that changes value with temperature. 100 ohms at 0 C, 138.5 ohms at 100 C. Accuracy is +/- 0.3 C. Max temp 600 C. Good for low temp and precision.
But: fragile wire, slow response (seconds), expensive, and needs 3 or 4 wire connection to cancel lead resistance.
Thermocouple
Two dissimilar metals welded at the tip. Produces a millivolt signal. K type goes to 1200 C. Accuracy is +/- 1.5 C. Fast response (milliseconds). Cheap and tough.
Good for: high temp ovens, plastic molds, die casting, anywhere rough.
Which to pick
- Below 300 C, precision needed: PT100 RTD
- Above 300 C, or rough environment: K type thermocouple
- Food/pharma where accuracy matters: PT100 Class A
A customer used K type thermocouple on a 180 C curing oven. Reading was off by 8 C. Swapped to PT100 and the oven held within 1 C. The difference was 3% of out-of-spec parts.
Need sensors matched to your process?
Tell us temp range and accuracy needed. We pick RTD or thermocouple.
Send Your Specs