Customers complain: parts at the top of the oven cure fine, parts at the bottom are still wet. The heater is not the problem - the airflow is.
Airflow patterns
- Horizontal airflow: supply on one side, exhaust on other, good for flat parts on racks
- Vertical airflow: supply from bottom, exhaust top, good for baskets and bulk parts
- Combined: supply from both sides, recirculating fan, most even, for precision curing
Velocity numbers
- General drying: 1 to 2 m/s on the product
- Paint curing: 2 to 3 m/s
- High temp sintering: 0.5 to 1 m/s, gentle
Recirculation ratio
Good ovens recirculate 80 to 90% of the air. Only 10 to 20% is fresh makeup. If you vent too much, you waste energy heating outside air.
A coating line in Wuxi had 15 C temperature difference between top and bottom of the oven. We added baffles on the supply duct and moved the fan to the middle. Difference dropped to 3 C.
Need a custom oven with even airflow?
Tell us part size, temp and throughput. We design the ductwork.
Send Your Specs