Mica band heaters are the workhorse of every injection molding shop. They wrap around the barrel, heat the plastic, and get replaced when they burn out.
How they are built
Nichrome wire wound on mica sheet, covered by stainless steel or galvanized shell. Mica handles up to 500 C. Standard widths are 25, 40, 60, 80 and 120 mm. Diameter matches your barrel to the mm.
Watt density matters
- Plastic barrel: 3.5 W/cm2 max
- Rubber extrusion: 4 W/cm2
- Die heating: 5 W/cm2
Go above 4 W/cm2 on a plastic barrel and the mica carbonizes. The heater turns white and opens up.
Why they blow at the lead
We see this every week. The lead exit is where 80% of failures start. Reasons:
- Barrel expands when hot, band stays tight - lead gets pulled
- Oil or water drips on the ceramic terminal block
- Thermal cycling cracks the nickel wire at the bend
A mold shop in Dongguan replaced 6 bands a month. We changed the lead exit from straight to 90 degree with flexible cable and added a stainless heat shield. Failures dropped 90%.
Installation tips
- Band must sit flat on the barrel - no gap
- Tighten the clamp evenly, not just one bolt
- Thermal paste between band and barrel cuts life by half? No wait - paste improves contact, we recommend it on high temp zones
- Keep thermocouple under the band at the middle of the heated zone
Need mica bands built to your barrel?
Tell us barrel diameter, width, voltage and zone wattage. We ship in 7 days.
Send Your Specs