Before energizing any new or stored heater, test insulation resistance with a megohmmeter (megger). 30 seconds of testing prevents a short circuit and a dead heater.
How to test
- Disconnect all wires from the heater terminals.
- Set megger to 500V DC (for 220V rated heaters). Use 1000V for 380V.
- Put one probe on the terminal, the other on the metal sheath or flange.
- Hold for 60 seconds. Read the value.
What the numbers mean
- Above 100 M ohm: dry and good. Energize it.
- 10 to 100 M ohm: slightly damp. Energize on low power for 30 minutes to dry out, then retest.
- Below 1 M ohm: wet or damaged. Do not turn on. Oven dry at 200 C for 4 hours, retest. If still low, the element is broken.
A customer in Dalian pulled a heater from storage, wired it up, and hit the breaker. The element was wet. We told them to megger before power. Next heater read 0.5 M ohm. We dried it in an oven for 4 hours. It came up to 200 M ohm. Saved a 12000 RMB heater.
When to test
- Before first install
- After long storage
- After moving the heater
- Once a year on immersion heaters in wet tanks