We Can't Quote Your Flanged Heater From Just "100kW 380V"

Every week we get an email: "Quote me a flanged heater, 100kW, 380V." We have to write back asking five more questions. If we just shipped what they asked for, the heater would likely burn out in 6 months.

Here's what we actually need before we can build you a heater that lasts.

1. What are you heating?

This is the most important question, and the one people skip. The sheath material and watt density depend entirely on the fluid.

We've seen customers order "100kW flanged heater" for a quench tank with 10% polymer solution. A 304 heater at 10 W/cm² scales and carbonizes in 3 months. The right answer was 316L at 4 W/cm².

2. Tank volume and temperature

We need to know: how many liters/gallons, what's the starting temp, what's the target, and how fast you need to get there. That tells us the kW. A 500L water tank from 20°C to 80°C needs about 40kW to heat in an hour. If you tell us "I want it hot," we can't size it.

Also tell us if the tank is insulated. An uninsulated outdoor tank in winter needs 20–30% extra kW just to hold temperature against heat loss.

3. Flange standard and size

Flanges aren't universal. We need to know: ANSI (150lb, 300lb), DIN (PN10, PN16), or Chinese standard. And the flange OD — 3", 6", 9", 12", 14". If you're replacing an existing heater, measure the old flange or send us a photo.

Bolt circle and number of holes matter too. We've shipped heaters that fit the flange size but bolted holes didn't line up because we guessed the standard. Don't make us guess.

4. Sheath length and mounting orientation

How deep can the elements go? If your tank is only 600mm deep, a 1000mm long bundle won't fit. And will it mount from the side, top, or bottom? Side-mounted needs a different tube bend pattern than top-mounted.

Critical: the elements must be fully submerged. If the liquid level drops during operation, the top of the bundle runs dry and burns out. We add low-level shutoff sensors for that.

5. Control and safety accessories

A bare flange heater with just power leads is asking for trouble. We recommend:

The difference between a heater that lasts 10 years and one that dies in 6 months is usually not the price — it's whether the manufacturer asked these questions before building. If a supplier quotes you instantly without asking what fluid you're heating, that's a warning sign.

Send us the 5 numbers

Fluid, tank volume / target temp, flange size and standard, sheath length, and voltage. We'll send back a drawing and quote within 24 hours.

Get a Quote & Drawing
Get a Quote