Flange Pressure Class: PN vs Class, and Why Temperature Cuts the Rating

When a customer sends a tank nozzle drawing, the first mark to match is the pressure rating. Pick too low and the joint leaks or bulges; pick too high and you pay for a flange the tank does not need.

The two rating systems

Chinese and European standards use PN (nominal pressure, in bar). ASME B16.5 uses Class (in pounds). The two are not exact equivalents, but for ordinary service they line up roughly as follows:

Rating drops as temperature rises

The stamped number is a room-temperature reference, not a value you keep at working heat. Steel loses strength as it gets hotter, so the maximum allowable pressure of the same flange falls on a pressure-temperature curve. A flange that holds 16 bar cold may hold less at 300 C.

What this means for heater flanges

A water tank at 60 to 90 C rarely needs more than PN16 or Class 150. A thermal oil tank running above 200 C, or a pressurized boiler, should move up one rating step even if the operating gauge looks modest. The gasket and bolts follow the same class as the flange.

Rule of thumb: match the PN or Class to the mating nozzle, then re-check that rating at the highest operating temperature. If the fluid is hot or pressurized, do not size by the cold pressure alone.