A flange heater bolts onto a tank nozzle, and the joint leaks most often not from the heater itself but from how the bolts were tightened. Going around the circle one bolt after another pulls the flange off parallel and pinches the gasket on one side.
Why the order matters
The gasket needs even compression all the way around. If you tighten bolts in sequence, the first side comes down hard while the opposite side still hangs loose. The flange tilts, the gasket slides, and one edge never seals. Under pressure the joint weeps at the loose side.
Cross (star) pattern
Number the bolt positions and work in diagonal opposite pairs. Start at any bolt, tighten the one directly across, then move 90 degrees and cross again. For an 8-bolt flange the order runs 1-5-3-7-2-6-4-8. The principle is the same for 4, 12 or 16 bolts: keep the load symmetrical as you go.
Three torque passes
Do not go straight to final torque in one step. Bring the joint up in staged passes using the same cross pattern each time:
- Pass 1: hand tighten, center the gasket, check the two flanges are parallel
- Pass 2: about 30 percent of target torque, recheck flange gap around the circle
- Pass 3: about 60 percent, further compress the gasket
- Pass 4: 100 percent target torque with a calibrated wrench
- Final check: one circular pass to confirm every bolt is at the same value
What causes leaks afterwards
- Gasket material wrong for the fluid, temperature or pressure
- Sealing face scratched, rusted or covered in weld spatter
- Flanges not parallel, forced together by the bolts
- Under-tightened: gasket pressure too low, fluid seeps through
- Over-tightened: gasket crushed or the flange face warped
On a hot oil or steam service, run the unit up to temperature, let it stabilize, then re-check the bolts. Heat changes the bolt load.
Torque is a sequence problem, not a force problem. Cross pattern, three rising passes, then a final even check. If the gasket leaks after that, look at the gasket and face before blaming the heater.